Detail Karya Ilmiah
Perbandingan CPOT dan Comfort Scale sebagai Instrumen Nyeri Pasien yang Terpasang Ventilator di ICU RSUP Dr. Soeradji Tirtonegoro Klaten
KURNIA DEVI SARASWATI, Kurnia Devi and Rosa Delima Ekwantini, Rosa and Sari Candra Dewi, Sari candra
(2020)
Perbandingan CPOT dan Comfort Scale sebagai Instrumen Nyeri
Pasien yang Terpasang Ventilator di ICU RSUP Dr. Soeradji
Tirtonegoro Klaten.
Caring : Jurnal Ilmiah Keperawatan, 9 (1).
pp. 34-42.
ISSN 1978-5752
Berkas Karya Ilmiah
PDF
Text
Perbandingan CPOT dan Comfort Scale sebagai Instrumen Nyeri Pasien yang Terpasang Ventilator di ICU RSUP Dr. Soeradji Tirtonegoro KlatenTURNITIN.pdf
Perbandingan CPOT dan Comfort Scale sebagai Instrumen Nyeri Pasien yang Terpasang Ventilator di ICU RSUP Dr. Soeradji Tirtonegoro KlatenTURNITIN.pdf
Abstract
Background: Ventilator is arespiratory aids was used for respiratory
failure patient. Critical condition of patients with ventilators will have
caused physical, psychosocial and spiritual problems. A ventilator tube in
the throat caused patient could not speak, pain and discomfort.
Assessment of pain in critical patients with ventilator is very necessary
because of the inability the patient for verifying. The Critical-Care Pain
Observation Tool (CPOT) and Comfort Scale are pain assessment
instruments for adult patients Purpose: This study aims to determinated comparation validity and
reliability of Critical-Care Pain Observation Tool (CPOT) and Comfort
Scale as pain instrument in patient installed ventilator at the ICU RSUP
Dr.Soeradji Tirtonegoro Klaten
Method: This research was used a cross sectional design. Sampling was
used consecutive sampling technique. Respondents were assessed two
times before and after suction using the CPOT and Comfort Scale
instruments. The samples of this research are 30 respondents. This
research was conducted in February-March 2020. The data has been
analyzed using Receiver Operating Curve (ROC) and Kappa Cohen.
Study Result: The result of the CPOT instrumen had a kappa value of 1,
sensitivity of 100%, specificity of 73,08% with AUC area of 0,875. While
the Comfort Scale instrumen had a kappa value of 1, a sensitivity of
54,55%, specificity of 100% with AUC area of 0,830.
Informasi Item
| Item Type | Article |
|---|---|
| Subjects | R Medicine > RT Nursing |
| Divisions | Poltekkes Kemenkes Yogyakarta > Jurusan Keperawatan |
| Date Deposited | 07 Apr 2023 04:37 |
| Last Modified | 07 Apr 2023 04:40 |
| URI | http://eprints.poltekkesjogja.ac.id/id/eprint/12055 |
